I. Overview
JY-8 series of static voltage relay voltage relay for the
introduction of integrated circuits (hereinafter referred to as the
relay) for the generators, transformers and transmission line
protection devices, as over-voltage protection, or blocking the
action of low-voltage components .
Imported digital relay switch, new switching power supply module
and imported intermediate relay, advanced electronic circuit
design, reasonable structure, China is currently the best
replacement products. The relay has the following distinctive
features:
1, the use of digital code switch operation voltage setting.
Intuitively easy setting to change the value without setting the
school inspection.
2, the relay for the integrated circuit static type, high accuracy,
setting error is less, less power consumption, no heat phenomenon.
3, Fast time, the return factor, wide tuning range.
4, high reliability, no shaking.
5, the relay terminal block dimensions and the base of the original
size of the electromagnetic type, terminal blocks and the same
shape, can completely replace the DJ, DY type voltage relay.
II. Model and specification
III. Technical parameters
1, the voltage setting range: 1 ~ 99V; 100 ~ 199V
2, AC auxiliary voltage: 200V, 100V; DC auxiliary voltage: 220V,
110V, 48V.
3, Power: AC circuit power consumption is less than 2 VA (maximum
tuning voltage value); DC circuit consumes less than 3W (exit after
the relay).
4, allow the change of DC auxiliary voltage range: 0.8 to 1.15
times the rating.
5, the action time: Low-voltage relay setting value of 1.5 times
the operating time of less than 30mS; over-voltage relay setting
value of 1.5 times the operating time of less than 20mS.
6, Return Time: Return Time Low voltage relay less than 25mS;
over-voltage relay to return time is not greater than 30mS.
7, the return factor: low-voltage relays to return coefficient is
less than 1.05; over-voltage relays return coefficient greater than
0.90.
8, setting the error: setting value in the 1V to the maximum range,
tuning error is less than 2%; in extreme temperatures, 1V any of
the above setting value of the error of not more than 3%; in the
auxiliary voltage limit range, the 1V above the value of any tuning
error is less than 3%.
9, contact capacity: long-term connected relay contacts 5A,
breaking capacity when the voltage does not exceed 250V, the
current does not exceed 2A, time constant 5mS the inductive load
for DC circuit 50W.
10, electrical life: Electrical Life no less than 10 million times.
11, insulation resistance: the open circuit voltage of 500V with
the following parts Megohmmeter measure the insulation
resistance300M (room temperature).
All conductive terminals and the exposed conductive metal or
between enclosures;
dynamic and static contact between;
contacts and exchanges between the circuit;
contact between the DC circuit;
normally open contact and normally closed contact between;
AC and DC circuit between the loop.
12, medium intensity: on the following sites should be able to
withstand AC voltage test under 1 minute should be no breakdown,
flashover.
All conductive terminals and the exposed conductive metal or
between the shell, 2000V/50Hz.
dynamic and static contact between the, 1000/50Hz.
contacts and exchanges between loop static and dynamic between,
1000V/50Hz.
contact between the DC circuit, 1000V/50Hz.
normally open and normally closed contact between the contacts,
1000V/50Hz.
AC and DC circuit loop between, 2000V/50Hz.
13, anti-jamming performance: high-frequency interference of
anti-relay meet DL478-92 "static relay protection and automatic
safety devices General" in the relevant regulations.
V. Internal terminal connection diagram relay